Chapter 4 Description of Functions
4-135
4
No.
Item
Description
(7)
Trigger target output
When the buffering mode is the trigger mode,
select the output to be used as the trigger target.
(8)
Trigger conditions
Select the occurrence conditions of the trigger,
when the buffering mode is the trigger mode.
(9)
Trigger point
(Specified for each head.)
When the buffering mode is the trigger mode,
specify the number of data to be accumulated in
advance before the reference for the reference
selected in the trigger conditions.
(10)
Trigger delay
When the buffering mode is the trigger mode,
specify the number of samplings to delay the
timing to detect the trigger. (Specify "0" if not
delaying the timing.)
(11)
Settings
Determines settings.
(12)
Cancel
Cancels settings.
Number of buffering measurements (Number of
accumulated data points)
For the buffering storage count, the maximum storage count varies depending
on the measurement mode selected for each head and the range specification.
Measurement mode
Maximum accumulation amount
Whole-synchro measurement
1,000 data for width ±6.25 mm
2400 data for width ±2.5mm
Multi-zone beam control measurement
Constant pitch measurement
100 μm pitch: 2400 data
Multi-select displacement sensing
2-locations specified: 86,400 data,
10-locations specified: 41,957 data