Chapter 4
Settings — [Layouts]
54 - ENGLISH
The software for S-curve projection enables selection of any output device on the layout. Since it enables S-curve correction for each active
output (red), it is recommended that all output devices be selected in this process. When all output devices to be corrected are selected,
and the source is evenly displayed in white for the output of the projector, then S-curve parameters can be adjusted. This operation adjusts
luminance of all blending portions. With careful adjustment, the optimal setting value to adjust the portions where luminance was too high or
too low on the initially projected image can be found.
Slide the bar or input a value to adjust [SCurve].
[Gamma]
Correct variability in gamma values among projectors. For the setting items of [Gamma], R, G, and B gamma values are displayed separately.
Change the input source from white to red, green, or blue. If there is a projector output with different luminance, then select the output in the
layout window (only the output becomes red), and input the appropriate gamma value to adjust the luminance and solve the variability in
images.
To adjust [Gamma], slide the bar or input a value for each item of [Red], [Green], and [Blue].
[Black Level Boost]
Position the input of black on the projector. When edge blending portions are checked in dark, sometimes light at the level that has not been
eliminated can be found. When [Black Level Boost] is adjusted, the luminance level of the center part of each output increases and matches
the joint parts.
Slide the bar or input a value to adjust [Black Level Boost].