解錠
通話
UNLOCK
復旧/警報音停止
非常
RESET/STOP ALARM
EMERG.
TALK
FIRE CONFIRM
MENU
OFF
火災
確認
終了
メニュー
電源
POWER
OPEN
Not Home
Lock
NOTHOME
Gas GAS
Fire FIRE
警戒
SET
83
If a Door Is Opened While the Security Alarm Is Active
ed
Note
Security 2
indication
flashing in
yellow
Alarm Stop
button
de)
Press the Alarm Stop button.
How to stop the call message
alarm
p
een
set
ne
After about 60 seconds
The security
alarm indicator
lamp flashing
in green
If a door is opened while the security alarm is
active, the magnet switch is turned on and the
security indication (security preliminary alarm)
is displayed on the base unit.
The Security Indicator
flashes in green while the
security alarm is active.
Approximately 100 seconds (factory default
setting) after the magnet switch is activated,
the event is reported to the manager room
and the handset of the door phone. If it was
an erroneous report, disarm the security
alarm within 100 seconds. When the security
alarm is disarmed, all the indicator lamps and
display are turned off. For information on how
to disarm it, refer to pages 102 to 103.
Installer
Setting
(beep) Security is operating.
(security preliminary alarm)
●
It is also possible to disable the call
message voice played while the security
preliminary alarm is active.
(only a beep sound is played.
)
●
You can choose the security alarm delay
time and the security preliminary alarm time
from 60, 120, 300 or 0 (immediately)
seconds
The factory default settings of Security 2 are
as follows:
Security alarm delay time: 60 seconds
Security preliminary alarm time: 60 seconds
●
It is also possible to report to the manager
room and handset of the door phone
immediately.
●
It is also possible not to report to the
manager room.
●
You can also change the screen displayed
while the security alarm is active.
Consult with the company that installed the
system or the administrating company.
After the security preliminary alarm
has sounded for 60 seconds, it
switches to the security alarm. The
behavior after switching to the
security alarm is the same as
Security 1 ( page 82).
(alarm sound) Security alarm has
activated. (security alarm)