Install a Power Supply
98
Oracle Server X5-2L Service Manual • May 2015
FIGURE 25
Installing a Power Supply
4.
Reconnect the power cord to the power supply.
5.
Verify that the amber Service Required LED on the replaced power supply and
the Service Required LEDs are not lit on the front and rear panels.
Note -
After you have replaced Power Supply 0, you might need to reset the Oracle ILOM
service processor (SP) to propagate the key identity properties (KIP) data to the new power
supply. For instructions on resetting the SP, see the
Oracle Integrated Lights Out Manager
(ILOM) 3.2 Configuration and Maintenance Guide
at
http://www.oracle.com/goto/ILOM/
docs
. Power Supply 1 does not contain KIP data, and therefore does not require an SP reset
after replacement.
6.
If you disconnected the two CMA left-side connectors, reconnect the
connectors.
For instructions for reconnecting the CMA left-side connectors, refer to
“Install the Cable
Management Arm” in “Oracle Server X5-2L Installation Guide ”
.