Remove the Right LED/USB Indicator Module
Servicing FRUs
201
See
“Reconnect Power and Data Cables” on page 233
and
“Power On the
Server” on page 233
. Verify that the power supply AC OK LED is lit.
Related Information
■
“Server System-Level Status Indicators” on page 31
■
“Remove the Left LED Indicator Module” on page 193
Remove the Right LED/USB Indicator Module
1.
Prepare the server for service.
a.
Power off the server and disconnect the power cords from the power
supplies.
See
“Powering Down the Server” on page 55
.
b.
Extend the server into the maintenance position.
See
“Extend the Server to the Maintenance Position” on page 61
.
c.
Attach an antistatic wrist strap to your wrist, and then to a metal area on the
chassis.
See
“Take Antistatic Measures” on page 64
.
d.
Remove the server top cover.
See
“Remove the Server Top Cover” on page 64
.
2.
Depending on your server's storage drive configuration, do one of the following:
■
If your server is configured with twelve 3.5-inch storage drives or twenty-
four 2.5-inch storage drives, perform the following procedures.
a.
Remove the server fan assembly door.
See
“Remove the Fan Assembly Door From the Server” on page 65
.
b.
Remove the four remaining No. 2 Phillips screws (two on each side of
the chassis) that secure the disk cage assembly to the server chassis.
Summary of Contents for X5-2L
Page 1: ...Part No E48333 04 May 2015 Oracle Server X5 2L Service Manual ...
Page 2: ......
Page 12: ...12 Oracle Server X5 2L Service Manual May 2015 ...
Page 24: ...24 Oracle Server X5 2L Service Manual May 2015 ...
Page 50: ...50 Oracle Server X5 2L Service Manual May 2015 ...
Page 70: ...70 Oracle Server X5 2L Service Manual May 2015 ...
Page 100: ...100 Oracle Server X5 2L Service Manual May 2015 ...
Page 268: ...268 Oracle Server X5 2L Service Manual May 2015 ...
Page 292: ...292 Oracle Server X5 2L Service Manual May 2015 ...