Install the Fan Assembly Door
228
Oracle Server X5-2L Service Manual • May 2015
Install the Fan Assembly Door
Note -
The procedures in this section should be used for systems configured with twelve 3.5-
inch storage drives or twenty-four 2.5-inch storage drives. If your system is configured with
eight 2.5-inch drives, see
“Install the Disk Cage Cover” on page 229
.
1.
Place the fan assembly door on the chassis and slightly over the fan assembly.
2.
Slide the fan assembly door forward and under the lip of the forward top cover
until it latches into place [1].
FIGURE 88
Installing the Fan Assembly Door
3.
Use a No. 2 Phillips screwdriver to install and secure the fan assembly door [2].
■
If your system is configured with twelve 3.5-inch storage drives, install and
tighten the two screws on each side of the chassis and the three screws on
top of the chassis.
■
If your system is configured with twenty-four 2.5-inch storage drives, install
and tighten the two screws on each side of the chassis.
Related Information
■
“Remove the Fan Assembly Door From the Server” on page 65
■
“Remove the Server Top Cover” on page 64
Summary of Contents for X5-2L
Page 1: ...Part No E48333 04 May 2015 Oracle Server X5 2L Service Manual ...
Page 2: ......
Page 12: ...12 Oracle Server X5 2L Service Manual May 2015 ...
Page 24: ...24 Oracle Server X5 2L Service Manual May 2015 ...
Page 50: ...50 Oracle Server X5 2L Service Manual May 2015 ...
Page 70: ...70 Oracle Server X5 2L Service Manual May 2015 ...
Page 100: ...100 Oracle Server X5 2L Service Manual May 2015 ...
Page 268: ...268 Oracle Server X5 2L Service Manual May 2015 ...
Page 292: ...292 Oracle Server X5 2L Service Manual May 2015 ...