Remove a Power Supply
Servicing CRUs That Do Not Require Server Power-Off
95
FIGURE 23
Power Supplies and Latches Locations
Figure Legend
1
Power supply 0
2
Power supply 1
A lit amber Service Required LED on a power supply indicates that a failure was detected.
You can also use the Oracle ILOM
show
faulty
command at the Oracle ILOM command-line
prompt (
->
) to identify a power supply failure.
Alternatively, to list all known faults in the server, log into the Oracle Solaris OS and issue
the
fmadm faulty
command, or log into the Oracle ILOM service processor from the Oracle
ILOM Fault Management Shell and issue the
fmadm faulty
command. For more information
about how to use the Oracle ILOM Fault Management Shell and supported commands, see the
Oracle ILOM User's Guide for System Monitoring and Diagnostics Firmware Release 3.2.x
in
the Oracle Integrated Lights Out Manager (ILOM) 3.2 Documentation Library at
http://www.
oracle.com/goto/ILOM/docs
.
Note -
The fans of a failed power supply might still be spinning when the system is powered on.
The fans will stop spinning when you disconnect the power cords.
Summary of Contents for X5-2L
Page 1: ...Part No E48333 04 May 2015 Oracle Server X5 2L Service Manual ...
Page 2: ......
Page 12: ...12 Oracle Server X5 2L Service Manual May 2015 ...
Page 24: ...24 Oracle Server X5 2L Service Manual May 2015 ...
Page 50: ...50 Oracle Server X5 2L Service Manual May 2015 ...
Page 70: ...70 Oracle Server X5 2L Service Manual May 2015 ...
Page 100: ...100 Oracle Server X5 2L Service Manual May 2015 ...
Page 268: ...268 Oracle Server X5 2L Service Manual May 2015 ...
Page 292: ...292 Oracle Server X5 2L Service Manual May 2015 ...