Remove NVMe Cables
Servicing FRUs
175
Related Information
■
“Servicing Storage Drives and Rear Drives (CRU)” on page 71
■
“Servicing the Front and Rear Storage Drive Backplanes (FRU)” on page 146
■
“Servicing SAS Cables (FRU)” on page 167
Remove NVMe Cables
1.
Prepare the server for service.
a.
Power off the server and disconnect the power cords from the power
supplies.
See
“Powering Down the Server” on page 55
.
b.
Extend the server to the maintenance position.
See
“Extend the Server to the Maintenance Position” on page 61
.
c.
Attach an antistatic wrist strap to your wrist, and then to a metal area on the
chassis.
See
“Electrostatic Discharge Safety” on page 52
.
d.
Remove the server top cover.
See
“Remove the Server Top Cover” on page 64
.
e.
Open the server fan assembly door and remove the fan modules.
See
“Remove a Fan Module” on page 89
.
f.
Swivel the air baffle into the upright position to allow access to the NVMe
cables.
g.
Depending on your server's storage drive configuration, do one of the
following:
■
If your server is configured with twenty-four 2.5-inch storage drives,
remove the server's front fan assembly door cover.
See
“Remove the Fan Assembly Door From the Server” on page 65
.
■
If your server is configured with eight 2.5-inch storage drives, remove
the server's disk cage cover.
Summary of Contents for X5-2L
Page 1: ...Part No E48333 04 May 2015 Oracle Server X5 2L Service Manual ...
Page 2: ......
Page 12: ...12 Oracle Server X5 2L Service Manual May 2015 ...
Page 24: ...24 Oracle Server X5 2L Service Manual May 2015 ...
Page 50: ...50 Oracle Server X5 2L Service Manual May 2015 ...
Page 70: ...70 Oracle Server X5 2L Service Manual May 2015 ...
Page 100: ...100 Oracle Server X5 2L Service Manual May 2015 ...
Page 268: ...268 Oracle Server X5 2L Service Manual May 2015 ...
Page 292: ...292 Oracle Server X5 2L Service Manual May 2015 ...