Remove a Power Supply
94
Oracle Server X5-2L Service Manual • May 2015
using hardware signaling between the PSU and motherboard circuitry, which can force the
system to throttle CPU and memory power in the event that a PSU is lost. The resulting power
savings will be enough to allow the system to continue to run (in a lower-performance state)
until the power problem is resolved.
The following status indicators (LEDs) are lit when a power supply fault is detected:
■
Front and rear Service Required LEDs
■
Amber Service Required LED on the faulty power supply
■
Rear Power Supply Fault LED located on the server front panel
If a power supply fails and you do not have a replacement available, leave the failed power
supply installed to ensure proper airflow in the server. For more information, refer to the
following topic and procedures:
■
“Power Supply Status Indicators” on page 33
■
“Remove a Power Supply” on page 94
■
“Install a Power Supply” on page 97
Related Information
■
“Troubleshooting Using the Server Front and Rear Panel Status Indicators ” on page 30
■
“Powering Down the Server” on page 55
Remove a Power Supply
1.
Prepare the system for power supply removal.
Refer to
“Take Antistatic Measures” on page 64
.
2.
Identify which power supply requires replacement.
Summary of Contents for X5-2L
Page 1: ...Part No E48333 04 May 2015 Oracle Server X5 2L Service Manual ...
Page 2: ......
Page 12: ...12 Oracle Server X5 2L Service Manual May 2015 ...
Page 24: ...24 Oracle Server X5 2L Service Manual May 2015 ...
Page 50: ...50 Oracle Server X5 2L Service Manual May 2015 ...
Page 70: ...70 Oracle Server X5 2L Service Manual May 2015 ...
Page 100: ...100 Oracle Server X5 2L Service Manual May 2015 ...
Page 268: ...268 Oracle Server X5 2L Service Manual May 2015 ...
Page 292: ...292 Oracle Server X5 2L Service Manual May 2015 ...