Remove a Rear Storage Drive
Servicing CRUs That Do Not Require Server Power-Off
87
b.
Grasp the drive latch, and pull the drive out of the drive slot [2].
Caution -
The drive latch is not an ejector. Do not open the latch too far to the right. Doing so
can damage the latch.
FIGURE 18
Removing a Rear-Mounted Storage Drive
5.
Consider your next steps:
■
If you are replacing the drive, continue to
“Install a Rear Storage Drive” on page 88
.
■
If you are not replacing the drive, install a filler panel in the empty drive slot to maintain
proper airflow and perform administrative tasks to configure the server to operate without
the drive.
For information on how to install a storage drive filler panel, see
“Remove and Install Filler
Panels” on page 226
.
Related Information
■
“Rear Panel Components and Cable Connections” on page 18
■
“Storage and Boot Drive Indicators” on page 32
■
“Remove an HDD or SSD Storage Drive” on page 73