Memory Events
Monitoring Components and Identifying SNMP Messages
313
Messages and Descriptions
Component Name
SNMP Trap:
sunHwTrapSensorNonCritThresholdExceeded
Oracle ILOM Event Message:
Upper noncritical threshold exceeded
Severity and Description:
Minor; A sensor has reported that its value has gone above an upper
non critical threshold setting or below a lower non critical threshold setting. This generic 'sensor'
trap is generated when the SNMP agent does not recognize the component type.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower.
/SYS/VPS_CPUS
/SYS/VPS_MEMORY
SNMP Trap:
sunHwTrapSensorThresholdOk
Oracle ILOM Event Message:
Upper noncritical threshold no longer exceeded
Severity and Description:
Informational; A sensor has reported that its value is in the normal
operating range. This generic 'sensor' trap is generated when the SNMP agent does not recognize
the component type.
/SYS/VPS_CPUS
/SYS/VPS_MEMORY
SNMP Trap:
sunHwTrapMemoryFault
Oracle ILOM Event Message:
event fault.cpu.intel.quickpath.link_slow "The Quickpath
Interconnect (QPI) link is operating below normal speed."
Severity and Description:
Major; A memory component is suspected of causing a fault.
/SYS/MB
SNMP Trap:
sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message:
event fault.cpu.intel.quickpath.link_slow "The Quickpath
Interconnect (QPI) link is operating below normal speed."
Severity and Description:
Informational; A memory component fault has been cleared.
/SYS/MB
SNMP Trap:
sunHwTrapMemoryFault
Oracle ILOM Event Message:
event fault.cpu.intel.quickpath.unknown-errcode "An unknown
error code from the Quickpath Interconnect (QPI) reference code has been detected."
Severity and Description:
Major; A memory component is suspected of causing a fault.
/SYS/MB
SNMP Trap:
sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message:
event fault.cpu.intel.quickpath.unknown-errcode "An unknown
error code from the Quickpath Interconnect (QPI) reference code has been detected."
Severity and Description:
Informational; A memory component fault has been cleared.
/SYS/MB
SNMP Trap:
sunHwTrapMemoryFault
Oracle ILOM Event Message:
event fault.memory.intel.dimm.none "An invalid memory DIMM
configuration has been detected."
Severity and Description:
Major; A memory component is suspected of causing a fault.
/SYS/MB
SNMP Trap:
sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message:
event fault.memory.intel.dimm.none "An invalid memory DIMM
configuration has been detected."
Severity and Description:
Informational; A memory component fault has been cleared.
/SYS/MB
SNMP Trap:
sunHwTrapMemoryFault
/SYS/MB
Summary of Contents for X5-2L
Page 1: ...Part No E48333 04 May 2015 Oracle Server X5 2L Service Manual ...
Page 2: ......
Page 12: ...12 Oracle Server X5 2L Service Manual May 2015 ...
Page 24: ...24 Oracle Server X5 2L Service Manual May 2015 ...
Page 50: ...50 Oracle Server X5 2L Service Manual May 2015 ...
Page 70: ...70 Oracle Server X5 2L Service Manual May 2015 ...
Page 100: ...100 Oracle Server X5 2L Service Manual May 2015 ...
Page 268: ...268 Oracle Server X5 2L Service Manual May 2015 ...
Page 292: ...292 Oracle Server X5 2L Service Manual May 2015 ...