Install a Rear Storage Drive
88
Oracle Server X5-2L Service Manual • May 2015
Install a Rear Storage Drive
Note -
Rear storage drives are supported in the twelve 3.5-inch storage drive and twenty-four
2.5-inch storage drive configurations only. Rear storage drives are not supported in the eight
2.5-inch storage drive configuration.
1.
If necessary, remove the drive filler panel.
2.
Determine the drive slot location for the replacement drive.
If you removed an existing drive from a slot in the system, you must install the replacement
drive in the same slot as the drive that was removed. Drives are physically addressed
according to the slot in which they are installed. See
“Rear Panel Components and Cable
Connections” on page 18
for boot drive locations.
3.
Slide the drive into the drive slot until it is fully seated.
FIGURE 19
Installing a Rear-Mounted Storage Drive
4.
Close the drive latch to lock the drive in place.
5.
Perform administrative procedures to reconfigure the drive.