![background image](http://html.mh-extra.com/html/omron/zx-t/zx-t_operation-manual_1633402097.webp)
94
S
e
c
tion 5
Us
in
g
t
h
e
Ze
ro
Re
s
e
t Func
tion
ZX-T
Operation Manual
Section 5
DETAILED SETTINGS
Setting Offset Values
Set an offset value when the reference value for zero reset is a value other than 0.
Moving to FUN and ZRDSP
1.
Set the mode switch to FUN.
2.
Use the LEFT and RIGHT Keys to display
ZRDSP on the main display.
Setting Offset Values
3.
Press the UP or DOWN Key.
The leftmost digit of the sub-display will flash.
4.
Use the Cursor Keys to set the offset value.
5.
Press the ENT Key to confirm the setting.
The offset value will be registered.
(mm)
POWER
ENABLE
ZERO
SUB
Move between digits.
Increment and decre-
ment the numeric value.
SUB