![background image](http://html.mh-extra.com/html/omron/zx-t/zx-t_operation-manual_1633402064.webp)
61
ZX-T
Operation Manual
Sec
tio
n 4
M
e
a
s
ur
in
g the
He
ight of
a
St
e
p
a
nd Fla
tne
s
s
Section 4
MAIN APPLICATIONS AND SETTING METHODS
Setting Tolerance Judgement Values
Set the upper and lower limits (the HIGH and LOW threshold values) for the PASS (OK)
judgement on height difference/flatness.
The HIGH, PASS, and LOW judgement results will be output based on the threshold
values set here.
Refer to
Section 5 Detailed Settings
for details on operation.
Inputting Threshold Values Directly, p. 78
Measurement result
Judgement
Measurement result > HIGH threshold
HIGH
LOW threshold
≤
measurement result
≤
HIGH threshold PASS
LOW threshold > measurement result
LOW
Summary of Contents for ZX-T -