![background image](http://html.mh-extra.com/html/omron/zx-t/zx-t_operation-manual_1633402124.webp)
121
ZX-T
Operation Manual
Ap
p
e
n
d
ices
Spe
c
if
ic
a
tions
a
n
d
Dime
ns
io
ns
APPENDICES
ZX-TDA11
ZX-TDA41
Measurement
period
1 ms
Possible settings for
number of samples
to average
(See note 1.)
1, 2, 4, 8, 16, 32, 64, 128, 256, 512 or 1024
Linear output
(See note 2.)
Current output: 4 to 20 mA/F.S., Max. load resistance: 300
Ω
Voltage output:
±
4 V (
±
5 V, 1 to 5 V, See note 3.), Output impedance: 100
Ω
Judgement outputs
(3 outputs:
HIGH/PASS/LOW)
NPN open-collector outputs,
30 VDC, 30 mA max.
Residual voltage: 1.2 V max.
PNP open-collector outputs,
30 VDC, 30 mA max.
Residual voltage: 2 V max.
Judgement output
hold input
ON: Short-circuited with 0-V terminal or 1.5 V
or less
OFF: Open (leakage current: 0.1 mA max.)
ON: Supply voltage short-circuited or within
supply voltage of 1.5 V max.
OFF: Open (leakage current: 0.1 mA max.)
Zero reset input
Timing input
Reset input
Functions
Indications
Judgement indicators: HIGH (orange), PASS (green), LOW (yellow), 7-segment main display
(red), 7-segment sub-display (yellow), power ON (green), zero reset (green), enable (green)
Power supply
voltage
12 to 24 VDC
±
10%, Ripple (p-p): 10% max.
Current
consumption
140 mA max. with power supply voltage of 24 V (Sensor connected)
Ambient
temperature
Operating and storage: 0 to 50
°
C (with no icing or condensation)
Ambient humidity
Operating and storage: 35% to 85% (with no condensation)
Insulation
resistance
20 M
Ω
min. at 500 VDC
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min
Vibration resistance
(destructive)
10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions
Shock resistance
(destructive)
300 m/s
2
3 times each in six directions (up/down, left/right, forward/backward)
Connection method Prewired (standard cable length: 2 m)
Weight (packed
state)
Approx. 350 g
Materials
Case: PBT (polybutylene terephthalate), Cover: Polycarbonate
Accessories
Instruction sheet
Measured value display
Present value display
Output value display
Set value display
ENABLE indicator
Zero reset indicator
Power ON indicator
Judgement indicator
ECO mode
Display reverse
Display digit limit
Zero reset
Zero reset memory
Initialization
Hysteresis width setting
Scale inversion
Span adjustment
Monitor focus
Linear output correction
Timing input
(A-B) calculations
(See note 4.)
(A+B) calculations
(See note 4.)
Clamp value setting
Key lock
Peak hold
Bottom hold
Sample hold
Peak-to-peak hold
Teaching
Direct threshold value setting
Self-peak hold
Self -bottom hold
Warming up display
Summary of Contents for ZX-T -
Page 1: ...OPERATION MANUAL Smart Sensors ZX T Series Cat No E346 E1 04 ...
Page 9: ...6 Preface Contents ZX T Operation Manual PREFACE ...
Page 15: ...12 Preface How to Use This Manual ZX T Operation Manual PREFACE ...
Page 16: ...Section 1 FEATURES 13 ZX T Operation Manual Section 1 FEATURES ZX T Features 14 ...
Page 53: ...50 Section 3 Function Transition Charts ZX T Operation Manual Section 3 BASIC OPERATION ...
Page 103: ...100 Section 5 Error Output Function ZX T Operation Manual Section 5 DETAILED SETTINGS ...
Page 113: ...110 Section 6 Initializing Settings Data ZX T Operation Manual Section 6 AUXILIARY FUNCTIONS ...