ZX-T
Operation Manual
Section 4
MAIN APPLICATIONS AND SETTING METHODS
Registering the Status With No Height Difference
Use the Zero Reset Function to set the status with no height difference. Use the CH2
Amplifier Unit to perform this setting.
Set a flat reference sample under the Sensor Heads.
Check to see if the zero reset offset value (ZRDSP) on the CH2 Amplifier Unit is set to zero before
you reset to zero. (Zero is the default setting.)
Setting Offset Values, p. 94
Switch the CH2 Amplifier Unit to RUN mode, and press and hold the ENT Key for at
least 1 s to reset to zero.
The status with no height difference (0) will be registered at the same timing that was
used when the zero reset was executed. Now the CH2 Amplifier Unit will display height
differences between the sensing points.
Refer to
Section 5 Detailed Settings
for details on operation.
Using the Zero Reset Function, p. 92
FUN
RUN
Press for 1 s min.
Reference value = 0
Summary of Contents for ZX-T -
Page 1: ...OPERATION MANUAL Smart Sensors ZX T Series Cat No E346 E1 04 ...
Page 9: ...6 Preface Contents ZX T Operation Manual PREFACE ...
Page 15: ...12 Preface How to Use This Manual ZX T Operation Manual PREFACE ...
Page 16: ...Section 1 FEATURES 13 ZX T Operation Manual Section 1 FEATURES ZX T Features 14 ...
Page 53: ...50 Section 3 Function Transition Charts ZX T Operation Manual Section 3 BASIC OPERATION ...
Page 103: ...100 Section 5 Error Output Function ZX T Operation Manual Section 5 DETAILED SETTINGS ...
Page 113: ...110 Section 6 Initializing Settings Data ZX T Operation Manual Section 6 AUXILIARY FUNCTIONS ...