ZX-T
Operation Manual
Section 5
DETAILED SETTINGS
Setting Number of Samples to Average
The number of samples to average is the number of data points used to average data
measured by the Sensor. The average value will be output.
Use the number of samples to average function to ignore sudden variations in measured
values. If the number of samples is increased, however, the response time of the judgement
outputs and linear output will be increased.
Moving to FUN and AVE
1.
Set the mode switch to FUN.
2.
Use the LEFT and RIGHT Keys to display
AVE
on the main display.
Selecting Number of Samples to Average
3.
Press the UP or DOWN Key.
The sub-display will flash.
4.
Use the UP and DOWN Keys to select the
number of samples to average.
5.
Press the ENT Key to confirm the selection.
The setting will be registered.
Selection for No. of
samples to average
Response time
1
2 ms
2
3 ms
4
5 ms
8
9 ms
16
17 ms
32
33 ms
64
65 ms
128
129 ms
256 (default)
257 ms
512
513 ms
1024
1025 ms
SUB
Summary of Contents for ZX-T -
Page 1: ...OPERATION MANUAL Smart Sensors ZX T Series Cat No E346 E1 04 ...
Page 9: ...6 Preface Contents ZX T Operation Manual PREFACE ...
Page 15: ...12 Preface How to Use This Manual ZX T Operation Manual PREFACE ...
Page 16: ...Section 1 FEATURES 13 ZX T Operation Manual Section 1 FEATURES ZX T Features 14 ...
Page 53: ...50 Section 3 Function Transition Charts ZX T Operation Manual Section 3 BASIC OPERATION ...
Page 103: ...100 Section 5 Error Output Function ZX T Operation Manual Section 5 DETAILED SETTINGS ...
Page 113: ...110 Section 6 Initializing Settings Data ZX T Operation Manual Section 6 AUXILIARY FUNCTIONS ...