80
S
e
c
tion 5
En
te
ri
ng Thr
e
s
hold V
a
lue
s
ZX-T
Operation Manual
Section 5
DETAILED SETTINGS
Hysteresis Setting
Set the hysteresis width for the upper and lower limits of judgements when the HIGH,
PASS, or LOW judgements are unstable near the threshold values
To prevent self-trigger chattering, set hysteresis for the self-trigger.
p. 71
Moving to FUN and HYS
1.
Set the mode switch to FUN.
2.
The main display will show HYS.
3.
Press the UP or DOWN Key.
The leftmost of the sub-display will flash.
4.
Use the Cursor Keys to enter the hysteresis
width.)
5.
Press the ENT Key to confirm the setting.
The hysteresis width will be registered.
Countermeasures for Setting Errors
If ERROV is displayed, HIGH threshold value
−
LOW
threshold value < hysteresis width.
If an error is displayed, the threshold values have not
been updated. Set the values again or change the
threshold values.
Operating value
Release value
HIGH threshold value
Measured value
LOW threshold value
Hysteresis (hysteresis width)
Output
Move between digits.
Increment and decre-
ment the numeric value.
Summary of Contents for ZX-T -
Page 1: ...OPERATION MANUAL Smart Sensors ZX T Series Cat No E346 E1 04 ...
Page 9: ...6 Preface Contents ZX T Operation Manual PREFACE ...
Page 15: ...12 Preface How to Use This Manual ZX T Operation Manual PREFACE ...
Page 16: ...Section 1 FEATURES 13 ZX T Operation Manual Section 1 FEATURES ZX T Features 14 ...
Page 53: ...50 Section 3 Function Transition Charts ZX T Operation Manual Section 3 BASIC OPERATION ...
Page 103: ...100 Section 5 Error Output Function ZX T Operation Manual Section 5 DETAILED SETTINGS ...
Page 113: ...110 Section 6 Initializing Settings Data ZX T Operation Manual Section 6 AUXILIARY FUNCTIONS ...