DETAILED SETTINGS
■
Finding the Height Difference
Use the expression A - B. Perform the setting at all Amplifier Units starting from the one
at CH2. The following describes the procedure for finding the height difference using
the CH2 Amplifier Unit as the example.
Moving to FUN and CALC
1.
Set the mode switch to FUN on the CH2
Amplifier Unit.
2.
Use the LEFT and RIGHT Keys to display
CALC on the main display.
Selecting Expressions
3.
Press the UP or DOWN Key.
The sub-display will flash.
4.
Use the UP and DOWN Keys to select the
expression type.
5.
Press the ENT Key to confirm the selection.
The expression will be registered.
CH1=B
CH2=A