ZX-T
Operation Manual
Section 5
DETAILED SETTINGS
13.
Press the ENT Key to confirm the setting.
The setting for the first point will be confirmed. The
screen for setting the second point will then be displayed.
Setting the Second Point (B)
14.
Use the same procedure as for the first point
to set the output current value and corre-
sponding measurement result for the second
point.
15.
Press the ENT Key to confirm the settings.
Confirming Completion of Monitor Focus Settings
The display will read OK if monitor focus has been set
correctly.
The display will be NG if the settings are incorrect.
If the settings are incorrect, check the following points
and execute the monitor focus again.
•
Is the measured value set on the sub-display within
the measurement distance (with scaling and calcula-
tion settings reflected if set)?
•
Are the first and second points separated by at least
1% of the rated measurement distance?
•
Are the current (or voltage) values for the two points
the same?
SUB
(mm)
POWER
ENABLE
ZERO
SUB
(mm)
POWER
ENABLE
ZERO
SUB
(mm)
POWER
ENABLE
ZERO
Summary of Contents for ZX-T -
Page 1: ...OPERATION MANUAL Smart Sensors ZX T Series Cat No E346 E1 04 ...
Page 9: ...6 Preface Contents ZX T Operation Manual PREFACE ...
Page 15: ...12 Preface How to Use This Manual ZX T Operation Manual PREFACE ...
Page 16: ...Section 1 FEATURES 13 ZX T Operation Manual Section 1 FEATURES ZX T Features 14 ...
Page 53: ...50 Section 3 Function Transition Charts ZX T Operation Manual Section 3 BASIC OPERATION ...
Page 103: ...100 Section 5 Error Output Function ZX T Operation Manual Section 5 DETAILED SETTINGS ...
Page 113: ...110 Section 6 Initializing Settings Data ZX T Operation Manual Section 6 AUXILIARY FUNCTIONS ...