![background image](http://html.mh-extra.com/html/omron/zx-t/zx-t_operation-manual_1633402075.webp)
72
S
e
c
tion 5
Usi
n
g
Hold
Fun
c
tion
s
ZX-T
Operation Manual
Section 5
DETAILED SETTINGS
Hysteresis width (for self trigger)
Set the hysteresis based on fluctuations in the measured values around the trigger level. When set,
hysteresis will be applied from the start of the sampling period and will prevent timing input chatter-
ing.
S-H (Sample hold)
Holds the measured value the moment the timing signal turns ON.
PP-H (Peak-to-peak
hold)
Holds the difference between the maximum and minimum values during the
sampling period. The sampling period is the period that the timing signal is ON.
This option is selected mainly when detecting vibration.
SP-H (Self-peak hold)
Holds the maximum value during the sampling period. The sampling period is
the period when the measured value is greater than the specified trigger level.
SB-H (Self-bottom hold)
Holds the minimum value during the sampling period. The sampling period is the
period when the measured value is lower than the specified trigger level.
Selection
Details
ON
OFF
Sampling period
Output
(Changes the
moment the
sampling period
is entered.)
Timing input
Maximum
value
Sampling period
Minimum
value
Output
(difference
between
maximum
and minimum)
ON
OFF
Timing input
Maximum value
Minimum
value
Sampling period
Trigger level
Maximum value
Output
Operating value
Release value
Hysteresis
width (for self
trigger)*
Sampling period
Trigger level
Minimum value
Output
Operating value
Release value
Hysteresis
width (for self
trigger)*
Summary of Contents for ZX-T -
Page 1: ...OPERATION MANUAL Smart Sensors ZX T Series Cat No E346 E1 04 ...
Page 9: ...6 Preface Contents ZX T Operation Manual PREFACE ...
Page 15: ...12 Preface How to Use This Manual ZX T Operation Manual PREFACE ...
Page 16: ...Section 1 FEATURES 13 ZX T Operation Manual Section 1 FEATURES ZX T Features 14 ...
Page 53: ...50 Section 3 Function Transition Charts ZX T Operation Manual Section 3 BASIC OPERATION ...
Page 103: ...100 Section 5 Error Output Function ZX T Operation Manual Section 5 DETAILED SETTINGS ...
Page 113: ...110 Section 6 Initializing Settings Data ZX T Operation Manual Section 6 AUXILIARY FUNCTIONS ...