Section 5
DETAILED SETTINGS
Using Hold Functions
The hold functions hold data for specific points during the measurement period (sampling
period), such as the maximum or minimum value, and output those values at the end of the
measurement period.
The value that will be held during the sampling period is selected here.
The CLAMP value is output until the first sampling period is finished.
CLAMP value, p. 88
Hold condition (which value to hold)
Sampling period
Output
Measurement starts*
Measurement ends*
* The timing input method depends on the hold conditions.
Value is held until the next time the
hold condition is met.
Current measured value
Selection
Details
OFF (default)
Hold measurement is not performed. The current measured value is always out-
put.
P-H (Peak hold)
Holds the maximum value during the sampling period. The sampling period is
the period that the timing signal is ON.
B-H (Bottom hold)
Holds the minimum value during the sampling period. The sampling period is the
period that the timing signal is ON.
ON
OFF
Output
Sampling period
Maximum
value
Timing input
ON
OFF
Output
Sampling period
Minimum
value
Timing input
Summary of Contents for ZX-T -
Page 1: ...OPERATION MANUAL Smart Sensors ZX T Series Cat No E346 E1 04 ...
Page 9: ...6 Preface Contents ZX T Operation Manual PREFACE ...
Page 15: ...12 Preface How to Use This Manual ZX T Operation Manual PREFACE ...
Page 16: ...Section 1 FEATURES 13 ZX T Operation Manual Section 1 FEATURES ZX T Features 14 ...
Page 53: ...50 Section 3 Function Transition Charts ZX T Operation Manual Section 3 BASIC OPERATION ...
Page 103: ...100 Section 5 Error Output Function ZX T Operation Manual Section 5 DETAILED SETTINGS ...
Page 113: ...110 Section 6 Initializing Settings Data ZX T Operation Manual Section 6 AUXILIARY FUNCTIONS ...