![background image](http://html.mh-extra.com/html/omron/zx-t/zx-t_operation-manual_1633402116.webp)
113
ZX-T
Operation Manual
Ap
p
e
n
d
ices
Ac
tu
a
to
rs
APPENDICES
The following commercial actuators can be mounted using the D5SN-TA conversion adapter.
Replacing Actuators
Be careful not to damage the rubber boot when replacing the actuator.
1.
Remove the standard actuator.
Hold the plunger’s D-cut section with radio pliers or a
similar tool while removing the actuator.
If the replacement must be performed by hold-
ing the Sensor Head itself, ensure that a
torque exceeding 0.15 N
⋅
m is not applied.
Applying excessive torque may have an
adverse affect on plunger operation.
2.
Mount the actuator or conversion adapter.
Hold the plunger’s D-cut section with radio pliers or a
similar tool while mounting and securing the actuator.
If the replacement must be performed by hold-
ing the Sensor Head itself, ensure that a
torque exceeding 0.15 N
⋅
m is not applied.
Applying excessive torque may have an
adverse affect on plunger operation.
Model
Appearance
Application
Bowl-shaped
Measurements on slip-
pery surfaces with rela-
tively minor height
differences.
Lever
Measurement of
narrow pitches.
Measuring film-
like sensing ob-
jects while sliding
over the side of
the sensing ob-
jects.
Lever bends by
90
°
.
D-cut section
Radio pliers or
a similar tool
Summary of Contents for ZX-T -
Page 1: ...OPERATION MANUAL Smart Sensors ZX T Series Cat No E346 E1 04 ...
Page 9: ...6 Preface Contents ZX T Operation Manual PREFACE ...
Page 15: ...12 Preface How to Use This Manual ZX T Operation Manual PREFACE ...
Page 16: ...Section 1 FEATURES 13 ZX T Operation Manual Section 1 FEATURES ZX T Features 14 ...
Page 53: ...50 Section 3 Function Transition Charts ZX T Operation Manual Section 3 BASIC OPERATION ...
Page 103: ...100 Section 5 Error Output Function ZX T Operation Manual Section 5 DETAILED SETTINGS ...
Page 113: ...110 Section 6 Initializing Settings Data ZX T Operation Manual Section 6 AUXILIARY FUNCTIONS ...