94
ANSI Z136.1:1993 "American National Standard for the Safety Use of Lasers"
Note:
LEGEND
X:
Shall
• :
Should
---:
No requirement
✩
:
Shall if enclosed Class 3b or Class 4
MPE:
Shall if MPE is exceeded
NHZ:
Nominal Hazard Zone analysis required
Control measures
Classification
Engineering Controls
1
2a
2
3a
3b
4
Protective Housing
X
X
X
X
X
X
Without Protective Housing
LSO shall establish Alternate Controls
Interlocks on Protective
Housing
✩
✩
✩
✩
X
X
Service Access Panel
✩
✩
✩
✩
X
X
Key Control
---
---
---
---
•
X
Viewing Portals
---
---
MPE
MPE
MPE
MPE
Collecting Optics
MPE
MPE
MPE
MPE
MPE
MPE
Totally Open Beam Path
---
---
---
---
X
NHZ
X
NHZ
Limited Open Beam Path
---
---
---
---
X
NHZ
X
NHZ
Enclosed Beam Path
None is required if 4.3.1 and 4.3.2 fulfilled
Remote Interlock Connector
---
---
---
---
•
X
Beam Stop or Attenuator
---
---
---
---
•
X
Activation Warning Systems
---
---
---
---
•
X
Emission Delay
---
---
---
---
---
X
Indoor Laser Controlled Area
---
---
---
---
X
NHZ
X
NHZ
Class 3b Laser Controlled
Area
---
---
---
---
X
---
Class 4 Laser Controlled Area
---
---
---
---
---
X
Laser Outdoor Controls
---
---
---
---
X
NHZ
X
NHZ
Laser in Navigable Airspace
---
---
---
•
•
•
Temporary Laser Controlled
Area
✩
MPE
✩
MPE
✩
MPE
✩
MPE
---
---
Remote Firing & Monitoring
---
---
---
---
---
•
Labels
X
X
X
X
X
X
Area Posting
---
---
---
•
X
NHZ
X
NHZ
Laser Product Classifications
Section 7-2
Summary of Contents for Z300 V3 - SETUP
Page 3: ...2 ...
Page 7: ...6 ...
Page 21: ...20 ...
Page 59: ...58 Long range Model Z300 S10 Super Long range Model Z300 S60 Mounting the Sensor Section 3 2 ...
Page 62: ...61 Z300 S10 Z300 S60 Mounting the Sensor Section 3 2 ...
Page 63: ...62 ...
Page 69: ...68 DIP Switch Settings Section 4 2 ...
Page 77: ...76 ...
Page 80: ...79 Z300 S10 Z300 S60 42 8 12 5dia 42 8 12 5dia Sensor Section 7 1 ...