81
Note 1:
Defined at 1/e
2
(13.5%) of the density at the light center. Light may, however, be
present outside this range and if the reflection factor of the light around the work-
piece is high compared to the workpiece, measurement may be affected.
Note 2:
Error with respect to the theoretical line representing the displacement output for
measurement of OMRON standard SUS blocks. The linearity varies with the
type of workpiece.
Note 3:
Error with respect to the theoretical line representing the displacement output for
measurement of OMRON standard quartz glass. The linearity varies with the
type of workpiece.
Note 4:
Error with respect to the theoretical line representing the displacement output for
measurement of OMRON standard white alumina ceramics. The linearity varies
with the type of workpiece.
Z300-S10
Note 5:
Displacement conversion value for peak-to-peak of displacement output. These
figures are for measurement of OMRON standard quartz glass (mirror reflection)
or OMRON standard SUS blocks (diffuse reflection) at the measurement center.
In magnetic fields, it may not be possible to maintain resolution performance
characteristics.
Note 6:
These figures are for when the Sensor is connected to the Z300-VC10EV3, the
average number of measurements is 256, and M command RS-232C output is
used.
Note 7:
Displacement conversion value for peak-to-peak of displacement output (for
measurement of OMRON standard white alumina ceramic at the measurement
center).
In strong magnetic fields, it may not be possible to maintain resolution perfor-
mance characteristics.
Note 8:
With the Z300-VC10EV3, at an average number of measurements of 64, and M
command RS-232C output is used.
Note 9:
With the Z300-VC10EV3, at an average number of measurements of 512, and
M command RS-232C output is used.
Note 10:
Value for measurement with 1 line (high speed) set in CCD Mode.
Note 11:
Value for measurement with the space between the Sensor and the workpiece
(Z300-S5/S10/S60: white alumina ceramic; Z300-S2: quartz glass) secured with
an aluminum jig.
Note 12:
Enquire separately about products conforming to IP67.
0.1%max.
80mm
120mm
Distance
120mm
80mm
Digital output
Sensor
Section 7-1
Summary of Contents for Z300 V3 - SETUP
Page 3: ...2 ...
Page 7: ...6 ...
Page 21: ...20 ...
Page 59: ...58 Long range Model Z300 S10 Super Long range Model Z300 S60 Mounting the Sensor Section 3 2 ...
Page 62: ...61 Z300 S10 Z300 S60 Mounting the Sensor Section 3 2 ...
Page 63: ...62 ...
Page 69: ...68 DIP Switch Settings Section 4 2 ...
Page 77: ...76 ...
Page 80: ...79 Z300 S10 Z300 S60 42 8 12 5dia 42 8 12 5dia Sensor Section 7 1 ...