Troubleshooting
This section provides information on hardware errors and remedies to be taken.
Refer to this section before requesting service from your OMRON representa-
tive.
6-1 Connection Errors
6-1-1 The Power Indicator is Not Lit.
The Power Supply is not connected properly.
The 24-VDC (21.6 to 26.4-VDC) supply voltage has dropped.
6-1-2 The Video Monitor is Blank.
The power to the Video Monitor is not ON.
The Monitor Cable is not connected properly.
The Video Monitor is malfunctioning.
When using an Liquid Crystal Monitor, the power supply capacity is insufficient.
6-1-3 Cannot Make Key Inputs from the Console.
The Console Cable is not correctly connected.
The DIP switch is set to NON VISUAL.
6-1-4 No Images are Displayed.
The Sensor cable is not connected to the Controller correctly.
There is no workpiece inside the measurement range.
The Sensor is not mounted in the correct position.
6-1-5 The Video Monitor Image is Not Clear.
There is electric noise entering from the power supply or cables.
The Monitor Cable is not connected properly.