93
User's Requirements
EN60825 (IEC60825)
With respect to the requirements of remote interlock connector, key control,
beam attenuator, and emission indicator, Class 3B laser products not exceeding
five times the AEL of Class 2 in the wavelength range of 400 to 700 nm are to be
treated as Class 3A laser products.
Note:
This table is intended to provide a convenient summary of requirements. See
text of standard for complete precautions.
JIS C6802
Note:
*Class 3B applies to any laser beam with a power of 5 mW maximum in the visi-
ble range of the laser beam.
Requirements;
Sub-clause
Classification
Class 1
Class 2
Class 3A
Class 3B
Class 4
Remote interlock
Not required
Connect to room or door circuits
Key control
Not required
Remove key when not in use
Beam attenuator
Not required
When in use prevents inadvertent
exposure
Emission
indicator device
Not required
Indicates laser in energized
Warning signs
Not required
Follow precautions on warning signs
Beam path
Not required
Terminate beam at end of useful length
Specular
reflection
No requirements
Prevent unintentional reflections
Eye protection
No requirements
Required if engineering and administrative proce-
dures not practicable and MPE exceeded
Protective
clothing
No requirements
Sometimes
required
Specific
requirements
Training
No requirements
Required for all operator and maintenance personnel
Item
Class 1
Class 2
Class 3A
Class 3B
Class 4
3B*
3B
Remote
interlock
Not required
Connect the remote interlock
of the laser beam to the
emergency main interlock,
the interlock of the room, or
the interlock of the door.
Key control
Not required
Do not keep the key in the
lock when the laser beam is
not used.
Beam breaker
or attenuator
Not required
Used to protect people from
accidental radiation by the
laser beam.
Warning sign
Not required
Post a proper warning sign on the door to the
room where laser beam equipment is installed.
Beam path
Not required
The laser beam must be terminated and, as a rule, must be enclosed. If the
laser beam is exposed, the vertical height of the beam must not be the
same as that of the eyes.
Mirror
reflection
Not required
Appropriate optical elements must be securely
attached and you must be able to control the opti-
cal elements during laser radiation.
Eye protec-
tion
Not required
Use eye protectors except in
special, specified locations.
Protection
clothes
Not required
Wear protection clothes if exposure of the skin to the laser
beam may exceed the MPE of the skin.
Training
Not required
The laser system must be operated by only properly trained
people.
Laser Product Classifications
Section 7-2
Summary of Contents for Z300 V3 - SETUP
Page 3: ...2 ...
Page 7: ...6 ...
Page 21: ...20 ...
Page 59: ...58 Long range Model Z300 S10 Super Long range Model Z300 S60 Mounting the Sensor Section 3 2 ...
Page 62: ...61 Z300 S10 Z300 S60 Mounting the Sensor Section 3 2 ...
Page 63: ...62 ...
Page 69: ...68 DIP Switch Settings Section 4 2 ...
Page 77: ...76 ...
Page 80: ...79 Z300 S10 Z300 S60 42 8 12 5dia 42 8 12 5dia Sensor Section 7 1 ...