In order to ensure performance, carry out the maintenance procedures given
below.
Notice
-Turn OFF the power and take safety precautions before conducting inspec-
tions. Electric shock can result from attempting safety inspections with the
power turned ON.
- Do not use thinners or benzene to clean the Z300.
5-1 Cleaning
- Remove dirt on equipment by gently wiping with a soft cloth.
Optical Filter on Front Panel of Sensor
- Use a blower brush (used to clean camera lenses) to blow large dust parti-
cles from the surface. Do not blow the dust away with your mouth.
- Use a soft cloth (for lenses) with a small amount of alcohol to remove the
remaining dust.
Notice
Do not use a scrubbing action when cleaning as scratches on the filter could
result in the Sensor malfunctioning.
5-2
Regular Inspections
Inspection point
Details
Tools
required
Power supply
The voltage measured at the power sup-
ply terminals must be 24 VDC +10%/
-10%.
Circuit tester
Ambient
temperature
The operating ambient temperature inside
the cabinet must be between 0 and 50
°
C.
Thermometer
Ambient
humidity
The operating ambient humidity inside
the cabinet must be between 35% and
85%.
Hygrometer
Installation
Each component must be firmly secured.
Each cable connector must be correctly
inserted and locked.
Phillips screw-
driver
Cleaning
Section 5-1
Summary of Contents for Z300 V3 - SETUP
Page 3: ...2 ...
Page 7: ...6 ...
Page 21: ...20 ...
Page 59: ...58 Long range Model Z300 S10 Super Long range Model Z300 S60 Mounting the Sensor Section 3 2 ...
Page 62: ...61 Z300 S10 Z300 S60 Mounting the Sensor Section 3 2 ...
Page 63: ...62 ...
Page 69: ...68 DIP Switch Settings Section 4 2 ...
Page 77: ...76 ...
Page 80: ...79 Z300 S10 Z300 S60 42 8 12 5dia 42 8 12 5dia Sensor Section 7 1 ...