Sensor Head is a Class 3B Laser Product according to EN60825-1 (IEC60825-1) and Class II Laser
Product according to FDA (21 CFR1040.10) (see note). The Z510 Series is meant to be built into final
system equipment. Pay special attention to the following precautions for the safe use of the product:
Note
:Europe: Class 2 and Class 3B of EN60825-1: 1994 = IEC60825-1: 1993
U.S.A.: Class II and Class IIIB of FDA (21 CFR1040.10).
(1)Use this product as specified in the operation manual. Otherwise, you may be exposed to
hazardous laser radiation.
(2)The Z300 series radiates laser beams in the visible light range. Do not expose your eyes directly to
the laser radiation. Ensure that the laser beam path is terminated during use. If a mirror or shiny
surface is positioned in the laser beam path, ensure that the reflected beam path is also terminated.
If the Unit must be used without terminating the laser beam path, position the laser beam path so
that it is not at eye level.
(3)To avoid exposure to hazardous laser radiation, do not displace nor remove the protective housing
during operation, maintenance, and any other servicing.
(4)The user should return the product to OMRON for all repair and servicing.
(5)As for countries other than those of Europe and the U.S.A., observe the regulations and standards
specified by each country.
As for the Laser Product Classifications, refer to the Appendix.
Refer to page 77.
Laser Safety
b
WARNING
The laser radiation has a high power density and exposure may result in loss of sight.
Do not to expose your eyes to the laser radiation either directly or indirectly (i.e., after
reflection from a mirror or shiny surface).
Z300-S2T
Z300-S5T
Z300-S10
Z300-S60
Wave length
650 nm
670 nm
670 nm
658 nm
Maximum pulse
duration
7 ms
7 ms
7 ms
17.5 ms
Cycle
0.5 to 10 ms
0.5 to 10 ms
0.5 to 10 ms
0.5 to 25 ms
Peak power
1 mW max.
1 mW max.
1 mW max.
15 mW max.
Class
2
3B
PRECAUTIONS
Summary of Contents for Z300 V3 - SETUP
Page 3: ...2 ...
Page 7: ...6 ...
Page 21: ...20 ...
Page 59: ...58 Long range Model Z300 S10 Super Long range Model Z300 S60 Mounting the Sensor Section 3 2 ...
Page 62: ...61 Z300 S10 Z300 S60 Mounting the Sensor Section 3 2 ...
Page 63: ...62 ...
Page 69: ...68 DIP Switch Settings Section 4 2 ...
Page 77: ...76 ...
Page 80: ...79 Z300 S10 Z300 S60 42 8 12 5dia 42 8 12 5dia Sensor Section 7 1 ...