2-7 Linear Sensor Controller Connections
2-7-1 Crimp Terminals and Cables
The terminal block uses M3 terminal screws. Use appropriate crimp terminals
for M3 screws as shown below. Tighten the screws to a torque of between 0.5
and 0.6 N
•
m.
Caution
Cover the terminal blocks with the Terminal Block Protection Covers. Uncov-
ered terminal blocks can result in electric shock.
2-7-2 Terminal Names
CHECK
Terminal 0 and the 4 to 20-mA terminal can be used for 1 to 5-V voltage output
by connecting the 250-
Ω
resistor provided.
Recommended Crimp Terminals
Manufacturer
Model
Recommended wire size
Forked
J.S.T. Mfg Co.,Ltd
V1.25-B3A
1.31 to 1.65mm
2
Round
J.S.T. Mfg Co.,Ltd
V1.25-MS3
Name
Application
4 to 20mA Analog output terminal for current output in the range 4 to 20 mA.
-5 to 5V
Analog output terminal for voltage output in the range -5 to 5 V.
0
Connected to input devices as a ground for analog output.
6.0 mm max.
6.0 mm max.
Forked
Round
Linear Sensor Controller Connections
Section 2-7
Summary of Contents for Z300 V3 - SETUP