25 of 135
1.4.4 Antenna Port
One to four OMRON Mono-static antennas (V740-HS01CA, V740-HS01LA) can be connected to the reader,
depending on the application requirements.
Connector: Reverse TNC
Name
Function
SG Signal
output
GND Ground
1. Connect required UHF antennas to the antenna ports on the reader.
IMPORTANT:
Connect antennas to the antenna ports before applying power to the reader. Any antenna
port that has detected no antenna will be disabled when the reader is powered on.
Antenna Connection: V750-BA50D04-SG(-MY)
Note:
With the two antenna configuration, there is a possibility that a tag may be read by an inactive
antenna if the tag is located with in approximately 20 cm of the inactive antenna with powered at 31.5 dBm.
2. Verify that all antennas are securely connected.
Antenna x 4
(V740-HS01CA/ V740-HS01LA)
Antenna Cable x 4
(V740-A01-3.0M/ V740-A01-10M/ V740-A01-20M)