1.4.3 Connect the Reader
Interface name and function
Note:
MAC Address is displayed on the lower part of RJ-45 Ethernet port.
Name
Function
Connector specifications
Antenna port
[ANT1- ANT4]
Connects with UHF mono-static type antenna
specified by OMRON via antenna cables.
Max 4 antennas can be connected to.
Reverse TNC
Ethernet port
[ETHERNET]
Connects with the host via a commercially
available 10/100Base-T cable.
RJ-45
LED Left: Link, Right: Act
RS-232C port
[RS-232C]
Connects with the host via a commercially
available RS-232C cable for DOS/V PC.
D-sub 9pin (male)
Inch screw (#4-40)
Input/Output port
[IN 1,2,3,4,C]
[OUT 1,2,3,4,C]
Connects to the input/output signal cable(s) via
an attached I/O port adapter (
MC 1,5/10-STF-
3,81
).
4 Inputs: connects with the sensor that works as
a trigger signal for communication start.
4 Outputs: connects with the light or actuator that
is driven by output signal.
MC 1,5/10-GF-3.81
(produced by PHOENIX
CONTACT).
DC Power input
[POWER DC12V]
Connects the Reader to an ex12VDC
power supply with the attached DC cable.
* Extension of DC cable is not allowable.
Exclusive connector
Control port
[CTRL PORT]
For future expansion.
Exclusive connector
Mode switch
(Not indicated)
Pushing this button for 1 second or more makes
the system rebooting with default setting, which
will be functional in case of system error or
setting unknown.
-
Ethernet
RS-232C
I/O port
Mode switch
DC power
input
Control port
Antenna port
Mono-Static x 4
Status indicators