2.2 System Interface
2.2.1 Command I/F Function
2.2.1.1 Ethernet, RS-232C Connection
Via 10/100BaseT Ethernet or RS-232C, the host issues a command to control the reader. As the control
method, V750 supports original procedures. Same commands are used via Ethernet and RS-232C.
(1) Ethernet
Ethernet is connected with the host such as server computer via TCP/IP protocol.
IP address corresponds to dynamic IP address assigned by DHCP server. You can choose the static IP
address (Default 192.168.1.200) or a dynamic IP address. Default setting is static IP address. The port 7090 is
used by reader for communication. IP address and the port number (over 1024) can be changed by using a
setting command or Web page. If the reader can not detect the DHCP server under dynamic IP address setting,
it will flash the error indicator and start up with static IP address.
Ethernet network settings
Item
Factory-default
DHCP Disable
IP Address
192.168.1.200
Subnet Mask
255.255.255.0
Gateway 192.168.1.254
Communication Port
7090
(2) RS-232C
The reader conforms to the RS-232C standard. It can connect with the host such as PLC. You can choose
following communication conditions.
Opptional communication conditions
Item
Factory-default
Setting value
Baud Rate (bps)
57600 bps
9600 / 19200 / 38400 / 57600 bps
Data Length (bit)
7 bit
7 / 8 bit
Parity Bit
Even
Even / Odd / None
Stop Bit (bit)
2 bit
1 / 2 bit
PLC
Via Ethernet (TCP/IP, Port:7090)
PC
Command
Response
Via RS-232C
Command
Response