37 of 135
2. Functions and Control
Reference Guide
This chapter lays the groundwork for the communication protocol between client software running on a remote
computer and the V750 reader.
2.1 Reader Operating Mode
Reader operating mode contains three modes, Operation Mode, Safe Mode and Update Mode.
Mode Function
Note
Operation Mode:
Under this mode, the reader
communicates tags normally.
Safe Mode:
Under this mode, the reader
recovers or is maintained
after error.
If you push the Mode Switch for 1 second or more
and release the switch while the system is
running, or if the reader detects an error (ex.
System error or a failure of firmware update), and
it can not start up normally due to this error, the
reader will start up under Safe Mode. Under this
mode, you can check the status via Web browser,
initialize the setting and install the firmware.
Update Mode:
Under this mode, the reader
updates firmware.