3.2.5 Example 5
Auto sorting with conveyor belt
This system enables the reader to read tag’s
addresses and to output signal when it detects the tags that
have target addresses.
Operating conditions in the reader
Item
Setting
Command at
startup
ID read is operated repeatedly in Single repeat mode when power turns on.
SETO iec=1 "RDID -seq SRP -ant 1"
Communicatio
n setup
Prevents over-rapped read (Buffur=5). No tag response is set.
SETC sbf=5 onr=1
SAVE
OUT1
Data match output setting: Data length is 96bit. If the first data is EPC 0x30, output signal
is on for 100ms.
SETO ot1=31 100 DAT==30**********************
OUT2
Data unmatch output: Data length is other than 96bit. If the first data is not 0x30, output
signal is on for 100ms.
SETO ot2=31 100 DAT!=30**********************
OUT3
Read result output: Output signal is on for 100ms when data is read.
SETO ot3=31 100
Communication sequence
100ms
100ms
(Data matched)
(Data matched)
Match output (OUT1)
Unmatach output
(OUT2)
100ms
(Data unmatched)
Read output (OUT3)
ID read
↓
ID read
↓
ID read
↓