66 of 135
Option shall be specified with values following the code that indicates option type.
Option Details
Code
Item
Specified Value
Default
Value
-seq
Communicat
ion
sequence
Specifies the communication sequence according to the operating conditions.
For only “Read ID” command, all parameters can be specified. For other
commands, only SOC can be specified.
-
SOC: Single Once
-
SRP:
Single
Repeat
-
MOC: Multi Once
-
MRP: Multi Repeat
-seq
SOC
-ant
Antenna
ID
Can specify the order of antenna to operate from 1
st
to 9
th
with figure of 1, 2, 3
and 4. The figure 1 to 4 means antenna’s identical number. If an antenna is
specified multiply, the antenna executes sequence multiply depend on the
order.
- Format: X ... XXXXXXXXX (Max 9 characters)
X: 1 to 4
-ant 1
-tmo
Timeout
Specifies time parameter for communication process in millisecond. The
numbers after rounding down to the 10 is added milliseconds as a specified
value (the least significant digit is always “0”). If the communication sequence
is SOC, the specified value is the communication time. If the value is
specified 0 (zero), communication process will continue until STOP command
is executed. If the communication sequence is SRP/MOC/MRP, the specified
value is maximum time between response (0 can’t be specified on
SRP/MOC/MRP sequence). (When you determine the value of Timeout, see
the section 5.2 “Communication Time”.)
-
Min:0ms
-
Max:2550ms(in DRM off)
10000ms(in DRM on)
-
Step:10ms
-tmo
250
-tif
Tag
Informatio
n
Specifies one or more items as additional information of tag communication
results that are output in the response. Specified item(s) shall be returned
according to the specified order with commas.
-
ANT: An antenna number which reads the tag first.
-
CNT: The count of tag read.
-
EPC: EPC code only.
-
PEP: PC bits and EPC code
-
PER: PC bits, EPC code, and CRC
For ID read, EPC/PRP/PER determines the EPC data type to be returned.
For ID write or Data write, if EPC/PEP/PER is specified, EPC data before
rewriting shall be returned. (If EPC data length is 0, it will be “*”.)
-tif EPC
-pwd
Password Specifies the password data with 32-bit, 8 digit numbers in hexadecimal
format for access of ID Write command, Data Read command, Data Write
command, and Lock command, and Kill password for Kill command. (0x not
required)
-
XXXXXXXX
For ID Write, Data Write, or Lock, if this option is omitted or
specified ”00000000”, Access password shall not be used .(If Access
password of the Tag is 0x00000000, the tag can be processed. For Kill
command, the Access password shall not be 0x00000000. If so, 7Fxx error
occurs.)
-pwd
000000
00
-ptc
Tag
Protocol
Specifies the number(s) that indicates the protocol type. Multiple numbers
can be specified.
-
2:
Class1
Generation2
-ptc 2