74 of 135
3.1.5.2 Reader Status, Reader Settings Function
To set the Reader Status and Reader Settings, following items shall be specified in the SET Reader command
(SETR) and GET Reader command (GETR). The Reader Status is available only for reading data.
Reader Status [Static / Read only] (
GETR
)
Code
Content
Fixed Value (=Factory Settings)
MFT Manufacturer “OMRON
Corporation”
TYP Type of the reader
“V750-BA50D04-SG” or “V750-BA50D04-SG-MY”
FWV Firmware version xxx-xxx-xxx-x
SER Serial number
“xxxxxxxx”
MAC MAC address
00:00:0A:89:xx:xx
Reader Status [Dynamic / Read only] (
GETR
)
Code
Content
Variable Value
ATS Antenna status
(Connected Antenna)
xxxxx (x:1 to 4)
-ex1. All antennas are connected: 1234
-ex2. Antenna #1 and antenna #4 are connected: 14
TTK Transition time from kick hhhh:mm:ss
-Min: 00:00:00
-Max: 9999:59:59
Reader Settings [Reader Information] (
GETR/SETR
)
Code
Content
User Setting Value
Factory Settings
RNM Reader name
Given string
-Min: 1 characters , ASCII
-Max: 63 characters, ASCII
-Note: This setting value has double
quotation marks.
(None)
RRL Reader’s role Given
string
-Min: 1 characters , ASCII
-Max: 63 characters , ASCII
-Note: This setting value has double
quotation marks.
(None)