(1) Set Operation (
SETO
)
This command is to write operation conditions into the nonvolatile memories in the reader. The new setting
shall be enabled at the upcoming startup.
Command
SETO(S)
Param1
=
Value1
<LF>
Note:
・
Putting equal between a single setting item and a setting value specifies the
value (no need to put ‘-‘ before setting item).
・
Multiple setting items can not be applicable.
Response
SETO[RC]<LF>
[RC]: Response Code
*(S) Space Character
Example 1) When the Response I/F after command execution is set RS-232C:
[Tx] SETO rif=2<LF>
[Rx] SETO0000<LF>
Example 2) When the executed command at the start up is set as [“RDID -ant 122322 -tmo 100”]:
[Tx] SETO iec=1 "RDID -ant 122322 -tmo 100"<LF>
[Rx] SETO0000<LF>
Example 3) When Input 1 function setting is set as [Command execution, start up edge, "RDID -ant 122322 -
tmo 100"] :
[Tx] SETO in1=1 0 "RDID -ant 122322 -tmo 100"<LF>
[Rx] SETO0000<LF>
Example 4) When output 3 function setting is set as [Signal is on for 2 seconds] when the executed command
is finished normally, the read data is 12bytes(24characters) and the 5
th
to 8
th
data is “0000”:
[Tx] SETO ot3=31 2000 dat==****0000****************<LF>
[Rx] SETO0000<LF>
Example 5) When output 4 function setting is set as[Signal is on for 1 second] if tag count is 10 or less:
[Tx] SETO ot4=31 1000 TCT<=10<LF>
[Rx] SETO0000<LF>
Example 6) When output 2 function setting is set as [Signal is on for 1 second] if both conditions on example 5
and 6 are fulfilled:
[Tx] SETO ot2=31 1000 DAT==****0000****************&TCT<=10<LF>
[Rx] SETO0000<LF>
Example 7) When output 2 function setting is set [Signal keep on when ERC(Communication error)]:
[Tx] SETO ot2=32 0<LF>
[Rx] SETO0000<LF>
Example 8) When output 2 function setting is set as [Signal is on for 2 seconds] if any code error of 71xx, 72xx
or 7Axx is occurred:
[Tx] SETO ot2=32 2000 71727A<LF>
[Rx] SETO0000<LF>
Example 9) When output 1 function setting is deleted:
[Tx] SETO ot1=00<LF>
[Rx] SETO0000<LF>