106 of 135
Description of Each Item
Reader Information
Item
Description
The range of the set code.
Default
Reader Name
Reader name defined by
its user.
Represented with from 1 to
63 ASCII characters.
(None)
Reader Role
The role of the reader
defined by its user.
Represented with from 1 to
63 ASCII characters.
(None)
Ethernet
Item
Description
The range of the set code.
Default
Host Name
Name to refer the host in
the network
Represented with from 1 to
63 ASCII characters.
V750-
BA50D04-SG
Domain Name
Domain name in the
network environment for
the reader.
Represented with from 1 to
67 ASCII characters.
(None)
DHCP Whether
the
reader
uses
DHCP serve or not.
Disabled / Enabled
Disabled
IP Address
IP address of the reader
192.168.1.200
Subnet Mask
The reader’s subnet mask
address.
255.255.255.0
Gateway
The reader’s Gateway
address.
192.168.1.254
TCP/IP Port
Port number of command
interface.
1025 to 65534
7090
RS-232C
Item Description
The range of the set
code.
Default
Baud Rate (bps)
Communication speed
9600 / 19200 / 38400 /
57600
57600
Data Bits
Communication data
length
7 / 8
7
Parity Bit
Parity bit
Even / Odd / None
Even
Stop Bit(s)
Stop bit
1 / 2
2
Action
[Save]
To save the setting of the reader,
enter the values and push [Save] button, then all the displayed
values are set in the reader's internal memory. They become effective as a default value after booting
next time. All the saving process is finished successfully, the reader displays "Successfully Saved" in the
page.
Saving process is executed in the displayed order, from the reader Information, Ethernet, to the RS-
232C.
If saving process is succeeded, the label changes its color from black to blue. If failed, it changes to red.
If the process fails to complete and stops, the latter items are not saved and they remain in black.