77 of 135
(2) Get Reader (
GETR
)
This command reads the current functional conditions in the reader. Even after SET Reader command (SETR)
is executed, the old information shall be read out unless the reboot is completed.
Command
GETR(S)
Param1
(S)
Param2
(S)...(S)
ParamN
<LF>
Note:
・
It specifies a parameter connecting a setting item to a setting value. (‘The setting item
does not have to be prepended with ‘ -‘ .)
・
In a single command multiple setting items can be specified by separating with space.
2 or more character spaces are acceptable for indicating separation.
Response
GETR[RC](S)[Param1=Value1](S)...(S)[ParamN=ValueN]<LF>
[RC]: Response Code
[ParamN=ValueN]: Setting item and value
Note:
・
If multiple items are specified, the reader shall return response with connecting
specified items to the setting values with equal in the specified order. Alphabetical
characters included in the item name in the response shall be small characters.
・
If the setting value includes any space, the space shall be enclosed with double
quotation.
*(S) Space Character
Example 1) When [Firmware version;100-100-100-0] is read:
[Tx] GETR fwv<LF>
[Rx] GETR0000 fwv=100-100-100-0<LF>
Example 2) When [Host name; V750-BA50D04, IP; 192.168.1.1, and Subnet mask; 255.255.255.0] is read:
[Tx] GETR lhn lip lnm<LF>
[Rx] GETR0000 lhn=”V750-BA50D04” lip=192.168.1.1 lnm=255.255.255.0 <LF>
Example 3) When [RS-232C Baud rate; 19200bps, Data length; 7 bits, Parity; even, and Stop; 1bit] is read:
[Tx] GETR rbr rdt rpb rsb<LF>
[Rx] GETR0000 rbr=19200 rdt=7 rpb=E rsb=1<LF>