86 of 135
(2) Get Operation (
GETO
)
This command allows the reader to read the current operation conditions. Even after setting operation
command (SETO) is executed, the old information shall be read out unless the reboot is completed.
Command
GETO(S)
Param1
<LF>
Note:
・
Specifies a single setting item. (not required ‘-‘ before the item)
・
Multiple setting items cannot not be specified.
Response
GETO[RC](S)[Param1=Value1]<LF>
[RC]: Response Code
[Param1=Value1]: Setting item and values
*(S) Space Character
Example 1) When executed command is read at startup:
[Tx] GETO iec<LF>
[Rx] GETO0000 iec=1 "RDID -ant 122322 -tmo 100"<LF>
Example 2) When Input 2 function setting is never registered:
[Tx] GETO in2<LF>
[Rx] GETO0000 in2=0 0<LF>
Example 3) When Input 1 function setting is read:
[Tx] GETO in1<LF>
[Rx] GETO0000 in1=1 0 "RDID -ant 122322 -tmo 100"<LF>
Example 4) When Input 3 function setting is read but the setting is not alive:
[Tx] GETO in3<LF>
[Rx] GETO0000 in3=0 0 "RDID -seq MOC -ant 123"<LF>
Example 5) When Output 4 function setting is never registered:
[Tx] GETO ot4<LF>
[Rx] GETO0000 ot4=00 0<LF>
Example 6) When Output 1 function setting is read:
[Tx] GETO ot1<LF>
[Rx] GETO0000 ot1=31 2000 DAT==****0000****************<LF>
Example 7) When Output 2 function setting is read and the setting is not alive:
[Tx] GETO ot2<LF>
[Rx] GETO0000 ot2=00 2000 DAT==****0000****************<LF>