83 of 135
Operation Settings [Programmable Output] (
GETO/SETO
)
Code
Content
User Setting Value
Factory Settings
OT1
Output port #1 function
setting
Format:
Timing
(S)
OutputTime
(S)
Condition
Timing
00:None
(User input)
11:RUN output
(The reader is running normally.)
12:ERR output
(The reader stopped with error.)
20:COM output
(The reader is communicating.)
2n:ATn Current antenna(s) (n=1 to 4)
(The reader is communicating
with specified antenna)
31:NML
(Evaluated normal completion)
32:ERC
(Evaluated completion with error
occurring)
OutputTime
10 to 9990 [ms]
0 (Status kept until upcoming evaluation.)
- Note: Output time is effective only for NML/
ERC setting.
Condition
-Note: Output time is effective only for NML/
ERC setting.
- Note: If the condition is omitted, output
signal shall be on without condition.
* Refer to the following list.
(None)
OT2
Output port #2 function
setting
Same as OT1
(None)
OT3
Output port #3 function
setting
Same as OT1
(None)
OT4
Output port #4 function
setting
Same as OT1
(None)