42 of 135
2.3.3 Self-Operation
This function enables the reader to start some works, judge, and output the results without instruction of
host by combining followings; registering command, setting reader status output, and setting communication
result judgment.
(1) Command entry
Commands can be registered in Startup and 4 digital inputs respectively.
Available conditions
Executing timing
Entered command
Reader: Startup
Power up or TCP/IP connection
Any given command
The rising edge of input #1 signal.
Any given command
The rising edge of input #2 signal.
Any given command
The rising edge of input #3 signal.
Any given command
The rising edge of input #4 signal.
Any given command
WARNING:
DO NOT enter the reset command at executing timing of start up.
IN1
IN2
IN3
IN4
Power On
Entered command
at Start Up
Start
process
End
process
If another command is running, the
entered command at IN3 starts.
But this command finished abnormally.
(Error code:15xx)
When the network is connected: (Response interface: Ethernet)
Entered command
at IN2
Start
process
End
process
Entered command
at IN3
Start
process
End
process