![background image](http://html1.mh-extra.com/html/omron/f3s-tgr-cl_a/f3s-tgr-cl_a_installation-and-operation-manual_741286058.webp)
44
SECTION 14
Specification and additional information
14-1 Specification
Performance
Protective height
500 mm, 800 mm, 900 mm and 1,200 mm
Beam pitch (center)
300 mm, 400 mm and 500 mm
Operating Range
F3S-TGR-CL-
K2C-500: 0.5m – 12.0m
K3C-800: 0.5m – 8.0m
K4C-900: 0.5m – 7.0m
K4C-1200:0.5m – 7.0m
F3S-TGR-CL-K_-___:
0.5 m – 20.0 m (short), default
20.0 m – 40.0 m (long), DIP SW option
F3S-TGR-CL-K_-____-LD:
25.0m – 50.0m
Effective Aperture Angle
For F3S-TGR-CL2:
±5° maximum, transmitter and receiver according to
IEC61496-2 (2006) for distances > 3 m
For F3S-TGR-CL4:
±2,5° maximum, transmitter and receiver according
to IEC61496-2 (2006) for distances > 3 m
Response Time (RT)
ON to OFF
Maximum: 13 ms
Light Source
Infrared Emitting LEDs, Wavelength 880 nm
Power Dissipation:
3 mW Class 1 acc. EN60825-1
Mechanical
Housing Material
Painted aluminum, Yellow, RAL 1018
Front Window Material
Acrylic Lexan
End Cap and Connector
Material
ABS
Sealing Gasket Material
EPDM
Mounting Bracket Material
Cold rolled Steel
Wiring connections
M12-connectors; 8-pin receiver and 4-pin transmitter
Weight
See table for more details
Environmental
Enclosure Rating
IP65
Operating Temperature
-10°C … +55°C
Storage Temperature
-25°C … +70°C
Relative Humidity
95% maximum, non-condensing
Vibration (IEC 60068-2-6)
10-70 Hz, 0.35 mm, maximum on all 3 axes
Shock (IEC 60086-2-29)
30 G for 16 ms, 1000 shocks on all 3 axes
Electrical
Power Input Transmitter
24 VDC ±20%, maximum current 70 mA
TEST Input
24 VDC ±20%, 10 mA typ.
Power Input Receiver
24 VDC ±20%, maximum current 100 mA
Receiver 180 mA (in muting) + OSSD1 250 mA +
OSSD2 250 mA
Input threshold Voltage
V
H
min = 17 VDC, V
L
max = 6 V
F06E-EN-03A+F3S-TGR-CL_K+OperManual.book Seite 44 Dienstag, 4. Oktober 2011 1:32 13