![background image](http://html1.mh-extra.com/html/omron/f3s-tgr-cl_a/f3s-tgr-cl_a_installation-and-operation-manual_741286024.webp)
10
Access to the selector switches
Section 6-1
6-1-2
Transmitter selector switch settings
Selector switches 5 - 8 are not used in the transmitter.
Please refer to the table below for the range setting:
Switch Position
Setting
Function
Default
1
OFF
RANGE SETTING
–
ON
SHORT RANGE X
2
OFF
RANGE SETTING
–
X
ON
LONG RANGE
3
OFF
CODE SETTING
NO CODING
X
ON
CODING
4
OFF
CODE SELECTION CODE A
ON
CODE B
SW-1
SW-2
Range selected
OFF
OFF
NOT ALLOWED
OFF
ON
LONG RANGE
ON
OFF
SHORT RANGE
ON
ON
NOT ALLOWED
F06E-EN-03A+F3S-TGR-CL_K+OperManual.book Seite 10 Dienstag, 4. Oktober 2011 1:32 13