xi
Alert statements in this manual
2
!WARNING
Make sure that the F3S-TGR-CL system is securely mounted and its cables
and connectors are properly connected.
!WARNING
Make sure that foreign objects such as water, oil, or dust do not enter the
inside of the F3S-TGR-CL system while the cover for the selector switches is
open and tighten the screws of the cover firmly after changing the settings.
!WARNING
Do not use the sensor system with mirrors in a retro-reflective configuration.
Doing so may hinder detection. It is possible to use mirrors to "bend" the
detection zone to a 90° angle.
!WARNING
Perform an inspection for all F3S-TGR-CL systems as described in the chap-
ter "Checkout and test procedure". When using series connections, perform
inspections for every connected F3S-TGR-CL system.
2-4
For wiring
!WARNING
Do not short-circuit the output line to the +24 V line. Otherwise, the output is
always ON. Also, the 0 V of the power supply must be grounded so that the
output does not turn ON due to grounding of the output line.
!WARNING
Configure the system by using the optimal number of safety outputs that sat-
isfy the requirements of the necessary safety category.
!WARNING
Do not connect each line of F3S-TGR-CL system to a DC power supply of
more than 24 VDC+20%. Also, do not connect to an AC power supply. Failure
to do so may result in electric shock.