38
Override
Section 11-3
•
If the entire protective field is free for more than 2sec. the override function
is immediately stopped.
•
A Test request on the TEST/RESTART input will stop the override function
immediately.
•
Maximum timeout for override is 600sec. After this timeout, the F3S-TGR-
CL system is restarting according to the interlock mode set by the selector
switches.
11-3-1 Override function at start-up
Conditions:
• At least one beam of the F3S-TGR-CL system must be blocked
• F3S-TGR-CL system is in MACHINE STOP mode.
Override function is stopped immediately if the TEST/RESTART input is acti-
vated during the Override function.
11-3-2 Override during operation cycle
Conditions
• At least one beam of the F3S-TGR-CL system must be blocked
• F3S-TGR-CL system is in MACHINE STOP mode.
• One or both muting inputs are active.
Override function is stopped immediately if the TEST/RESTART input is acti-
vated during the Override function
1
2
3
4
Wait < 5 s
5
6
7
8
9
> 5 s
OVERRIDE START.
LMS flashes
To avoid EDM error at
override function end
End of
OVERRIDE
RESTART
+24VDC
RESTART
+24VDC
1
2
3
4
< 1 s
< 1 s
< 1 s
< 1 s
5
6
7
8
9
< 1 s
> 1 s
OVERRIDE
START.
LMS flashes
> 2 s
End of OVER-
RIDE
RESTART
+24VDC
RESTART
+24VDC
RESTART
+24VDC
RESTART
+24VDC
RESTART
+24VDC
RESTART
+24VDC