![background image](http://html1.mh-extra.com/html/omron/f3s-tgr-cl_a/f3s-tgr-cl_a_installation-and-operation-manual_741286060.webp)
46
Specification
Section 14-1
Conformity
AOPD(ESPE)
F3S-TGR-CL2: Type 2 acc. to EN 61496-1/A1 (2008)
and IEC 61496-2 (2006)
F3S-TGR-CL4: Type 4 acc. to EN 61496-1/A1 (2008)
and IEC 61496-2 (2006)
Safety category
F3S-TGR-CL2 system is suitable for safety control
systems up to Category 2 acc. EN ISO 13849-1
(2008)
F3S-TGR-CL4 system is suitable for safety control
systems up to Category 4 acc. EN ISO 13849-1
(2008)
Safety Integrity Level
F3S-TGR-CL system is suitable for up to SIL 3 per
IEC 61508
Performance level (PL)
F3S-TGR-CL2 system is suitable for safety control
systems up to Performance level c acc. EN ISO
13849-1 (2008)
F3S-TGR-CL4 system is suitable for safety control
systems up to Performance level e acc. EN ISO
13849-1 (2008)
Mean time to dangerous fail-
ure (MTTFd)
100 years
Diagnostic Coverage (DC)
High acc. EN ISO 13849-1 (2008)
Mean time to repair (MTTR)
8 hours
PFH
2.5 * 10
-09
Proof test interval
Every 20 years
F06E-EN-03A+F3S-TGR-CL_K+OperManual.book Seite 46 Dienstag, 4. Oktober 2011 1:32 13