70
Wiring examples
Section 17-3
17-3-5 F3S-TGR-CL and G7SA-3A1B and EDM function
Note
For Active - Passive systems please keep in mind there is no wiring on Trans-
mitter (Passiv) side.
Note
The achievable safety category or performance level using this circuit
depends on the safety light curtain in use and the correct wiring of the safety
control unit.
Note
This circuit can achieve a PL=e acc. ISO 13849-1 if a F3S-TGR-CL-4_ is
used.
Shield
Mut.
B (Y
ello
w)
+24 (Bro
wn)
OSSD1 (Pink)
Te
st (White)
+24 (Bro
wn)
OSSD2 (Gr
ay)
Te
st/resta
rt (White)
0VDC (Blue)
Mut.
A (Green)
Mut.
Lamp (Red)
Shield
0VDC
R
S
T
F3S-TGR-CL
11
23
33
43
44
34
24
12
0
1
11
23
33
43
44
34
24
12
0
1
RESTART
TEST
M
24Vdc +
-
G7SA-3A1B
G7SA-3A1B
RECEIVER
TRANSMITTER
F06E-EN-03A+F3S-TGR-CL_K+OperManual.book Seite 70 Dienstag, 4. Oktober 2011 1:32 13