35
Muting and override
Section 11-1
11-1-5-3
X-activation mode
The X-muting activation mode can be used in applications where material is
transported in both direction. This muting mode is used in applications, where
eg. pallets are used to carry stacked boxes or crates. Most stable detection of
this kind of material is possible using the X-muting activation mode.
Two muting sensors are connected to the two Muting inputs, Muting A and
Muting B.
Firmware 1.3.6
To control and activate the mut-
ing function, the inputs
• Muting A
• Muting B
• External Muting lamp
connection (LMS)
are used.
!WARNING
This muting activation mode can only used in uni-directional transport. Failure
to do so may result in serious injury.
!WARNING
The crossing point of the two muting sensors MUST be inside the dangerous
zone. Failure to do so may result in serious injury.
Note •
d is the resulting distance between the activation points of Muting A and
Muting B. It needs to be checked in regards to the speed of the material
transport.
Timing requirements and limitations:
• Either Muting A or Muting B can be used to initiate the muting function.
• There is no maximum time limit after Muting A is activated.
• There is no maximum time limit after Muting B is activated.
• Muting A and Muting B cannot be activated at the same time. A minimum
time difference equal to the response time of the sensor is mandatory.
• Maximum muting time is 1700 sec. After this time, muting function is
stopped even if the Muting inputs are still active.
24 Vdc
Shield
RL
250mA
max
RL
250mA
max
OUT
1
OUT
2
Muting A
TEST/REST
AR
T
LMS
Muting B
0 Vdc
RECEIVER
BROWN BLUE WHITE GREEN YELLOW RED
GRAY
PINK
SHIELD
GOODS
Mut sen.
A
Mut sen.
B
FENCE
d5
DIRECTIONS
ALLOWED
DANGEROUS
AREA
SAFE
AREA